What We Offer
Product Introduction
The solvent-free polyurethane waterproofing membrane is engineered for long-lasting elasticity, seamless protection, and demanding waterproofing applications. Designed as a cold-applied, cold-curing single-component system for roofs, water tanks, pools, and complex structural details.
Project-Based Insights
Hot year-round, 27–28°C. Wet season May–Nov with heavy rain (~2,000 mm). Dry season Dec–Apr. Abundant sunshine (~2,500 h). UV index very high, typically Aug to Sep.
Weidun has appointed the following regional distributors in Southeast Asia:
Matrix Chemical – Ho Chi Minh City, Vietnam
Tmassif Construction Chemical – Manila, Philippines
Weidun®LQ001 is engineered for monsoon-prone regions where roofs, balconies, and other areas need a seamless moisture barrier. Its solvent-free composition also makes it suitable for potable water tanks and seafood pools commonly used across Southeast Asia.

Humidity Resistance

Service Life
Desert climate, scorching summers over 40°C, mild winters. Extremely arid (~60 mm rain). Year-round intense sunshine (~3,900 h). UV index very high, reaching 8–11.
Weidun has appointed the following regional distributors in the Middle East:
Procare Building Supplies – Dubai, UAE
Izomaks – Riyadh, Saudi Arabia
Our polyurethane liquid membrane maintains elasticity even under harsh thermal cycling. Its cold-applied installation also improves site safety by eliminating open flame torch application risks.

High Temperature Endurance

Water Pressure Ressistence
Mediterranean semi-arid climate, hot dry summers 26–27°C, mild wet winters (~317 mm rain). Abundant sunshine (~3,900 h). UV index high, 8–9 in summer.
Weidun has appointed the following regional distributors in North Africa:
From coastal infrastructure to inland commercial developments, this liquid membrane performs reliably in regions with fluctuating temperatures and demanding environmental exposure. Its low water absorption and crack-bridging performance help maintain long-term waterproofing integrity while reducing maintenance requirements.

Protection Excellent

Waterproof Integrity
Quick Product Guide
Everything contractors, architects, and project owners need to know before selecting this waterproofing system.
Weidun®LQ001 creates a fully bonded, joint-free waterproofing layer that adapts to irregular surfaces and difficult detailing zones. Unlike sheet membranes that necessitate overlapping seams, this liquid-applied polyurethane coating forms a continuous elastic barrier that can seal corners, pipe penetrations flashing details, and curved surfaces with precision. Its high crack-bridging ability and exceptional elongation make it ideal for structures exposed to movement, vibration, and thermal expansion.
Weidun®LQ0001 is used to create a seamless waterproofing barrier on roofs, balconies, water tanks, seafood pools, and complex structural details such as corners, pipe penetrations, and curved surfaces. Its high elasticity and crack-bridging performance make it ideal for structures subject to movement, thermal expansion, and harsh climate exposure.
Applying solvent-free polyurethane lining in a water tank involves surface preparation, primer application, multi-coat application, curing, and final testing. The concrete substrate must be cleaned, repaired, and pre-wetted to SSD condition, followed by a compatible primer to seal pores and boost adhesion. The solvent-free PU, mixed at a 1:1 ratio, is then applied in 2–3 coats to reach the required dry film thickness (typically 1.5–2.0 mm), with each coat allowed to tack off before the next. The system cures at ambient temperature for 7 days to achieve full mechanical and chemical resistance, after which a 24-hour water-tightness test is carried out to confirm leak-proof performance prior to commissioning.
Why Choose US?
Weidun®LQ001 is manufactured for long-term waterproofing performance in both commercial and infrastructure projects. With over 20 years of waterproofing manufacturing and export experience, our Weidun products are trusted across more than 35 countries around the world.
Unlike cementitious coatings or rigid waterproofing systems, this polyurethane membrane remains permanently flexible after curing. It stretches with substrate movement, bridges cracks, and resists long-term water immersion without losing waterproofing integrity.

VOC content tested at only 16g/L, significantly below standard limits.

Elongation reaches up to 760% based on ASTM D412-16 (2021) testing.

Passed hydrostatic pressure testing at 1.5 bar for 7 days with zero penetration.

Suitable for potable water tank waterproofing because of its solvent-free formulation.
Products Comparison
Solvent-free PU creates a seamless waterproof barrier without joints or overlaps. This membrane conforms perfectly to complex detailing areas while maintaining long-term elasticity and waterproofing stability.
Best for indoor waterproofing & Portable water project. A cost-effective waterproofing system widely used.
Technical Performance
Key Metric | Solvent-Free PU Membrane | Cement Polymer Membrane |
Primary Use | Potable water tanks, pools, roofing, complex details | Indoor waterproofing, Portable wanter tanks, pools |
Waterproofing Performance | Excellent under long-term immersion | Moderate |
VOC Content | Extremely low | Low |
Elasticity | Very high | Moderate |
Outdoor Suitability | Excellent | Limited |
Crack Bridging | Superior | Standard |
Weather Resistance | High | Moderate |
Cost | High | Lower |
As a flexible membrane, solvent-free polyurethane (PU) offers superior elasticity, tensile strength, and corrosion resistance compared to rigid cementitious coatings. This makes it the preferred choice for potable water applications subject to structural movement or requiring critical crack-bridging capabilities. While polyurethane comes at a higher initial material cost, choosing between PU and cementitious systems requires EPC contractors and project owners to weigh upfront CAPEX against long-term performance and lifecycle value.
Expert-Insight
Clean and grind the concrete substrate. Repair honeycombs and cracks. Pre-wet the surface to saturated-surface-dry (SSD) condition.
Apply a compatible epoxy or PU primer to seal pores and enhance adhesion.
Mix the solvent-free PU at a 1:1 ratio. Apply in 2–3 coats (by trowel or spray) to reach the specified DFT (typically 1.5–2.0 mm). Allow each coat to become tack-free before applying the next.
Allow the system to cure at ambient temperature for 7 days for full mechanical and chemical resistance.
Perform a 24‑hour water-tightness test before commissioning.
Testimonials
During our initial communication, I was concerned that too many customization requests might be difficult to fulfill. However, WEIDUN Company has satisfied almost all of them.

Minh Nguyen - Vietnam
As a subcontractor, every time after the construction inspection, the main contractor is extremely satisfied with our product quality. This has been our sixth year of cooperation with WEIDUN.

Admad Arif - Dubai
The temperature difference between day and night in our region is quite significant. However, the products of WEIDUN have withstood the test. Although the prices of these products are relatively high, they have indeed been flawless.

Saleh Abbas - Libya
During our initial communication, I was concerned that too many customization requests might be difficult to fulfill. However, WEIDUN Company has satisfied almost all of them.

Minh Nguyen - Vietnam
As a subcontractor, every time after the construction inspection, the main contractor is extremely satisfied with our product quality. This has been our sixth year of cooperation with WEIDUN.

Admad Arif - Dubai
The temperature difference between day and night in our region is quite significant. However, the products of WEIDUN have withstood the test. Although the prices of these products are relatively high, they have indeed been flawless.

Saleh Abbas - Libya
Production To Shipment
Choose the Right Products
Our product line is manufactured to match the specific technical demands of underground civil engineering and industrial roofing.
FAQ’s
Weidun®LQ001 is a solvent-free polyurethane membrane designed to remain permanently elastic after curing. Unlike rigid cementitious coating system, it stretches with substrate movement and forms a seamless waterproof barrier without joints or overlaps.
Yes. Its solvent-free formulation and ultra-low VOC content make it suitable for potable water tank and waterproofing applications.
Yes. Weidun®LQ001 is designed for areas exposed to permanent moisture and passed hydrostatic pressure testing at 1.5 bar for 7 days with zero water penetration.
Yes. Polyurethane waterproofing offers excellent elasticity and weather resistance, making it highly effective for outdoor roofs and exposed waterproofing areas.
The membrane can be applied using a roller, brush, or spray equipment depending on the project size and substrate conditions.
Get in Touch
Weidun is committed to transparency and sustainability. Please fill out the form below, and our experts will get in touch with you.
Choose your time-proven waterproofing materials and solutions, backed by our experienced technical team.
Weidun is committed to transparency and sustainability. Please fill out the form below, and our experts will get in touch with you.
Weidun is committed to transparency and sustainability. Please fill out the form below, and our experts will get in touch with you.